Lighting Lab
Lighting Lab
Lighting Lab (Lamps and Lights)
1- Introduction of the Lighting Laboratory:
Lighting Laboratory of Energy Industries Laboratories as one of Tavanir approved laboratories for performing Tavanir Directive tests for LED street lights (approved by vendor Tavanir) as well as one of the first neutral laboratories collaborating with the Institute of Standards and ISO 17025 and traceable by ILAC in the field of complete tests of lamps and lights (Safety, Performance, EMC, IP, ATEX.
This laboratory is also active in numerous projects of Tavanir, municipalities, government projects and for export and import (customs) as well as receiving CE marking which further clarifies the need for the presence of an internationally recognized reference laboratory for quality assessment and technical inspection.
2-The purpose of testing and providing services in the lighting laboratory of energy industries can be described in the following ways:
2.1 Providing services to manufacturers such as:
– Performing typing test products in the lighting industry with ILAC international traceability
– Testing and issuing international certificates (CE, ATEX) in accordance with European Directives IMQ Italy and SZU TEST Turkey
– Consulting and performing the necessary tests to obtain the standard mark for manufactured products
– Reviewing the production process of products and discovering and eliminating possible defects in the production process before standard sampling
– Technical advice to equip the laboratory and the necessary training in this field
– Qualitative advice for implementation of systems and obtaining related documents
– Performing inspection and audit of production lines
2.2 Providing services to importers such as:
– Performing related affairs to obtain import permits of goods
– Reviewing and announcing the necessary standards for entering the goods and performing related tests
– Guidance for the process of purchasing and entering the goods and necessary advice before purchasing the goods and checking and announcing possible defects
This laboratory also works in numerous projects of Tavanir, municipalities, government projects and for export and import (customs) as well as receiving CE marking which clarifies the need for the presence of an internationally recognized reference laboratory for quality assessment and technical inspection.
3-Standards and products covered by:
Perform all safety tests, performance, electromagnetic compatibility and explosion proof tests for the following products:
- Lamps, modules and lights such as: CFL, LED, mercury vapor and sodium
- Types of drivers and launchers
- Energy Label Tests
Tests that can be performed along with standards for related products:
Standard Title | ISIRI | IEC |
Self-contained LED ballast lamps for general lighting purposes with a supply voltage greater than 50 V – Performance requirements
| ISIRI 20422 | IEC 62612 |
• Measurement of electrical and photometric parameters • Radiation intensity and angle test • Aging test (normal-accelerating) • Keying test | ||
Self-contained LED ballast lamps for use in public lighting over V50 – safety requirements | ISIRI 14434 | IEC 62560 |
• Mechanical Endurance Test (Bending Torque-Torque Tensile) • Flame and Spark Resistance Test • Insulation Resistance Test • Electrical Endurance Test • Temperature Resistance Test | ||
Criteria and technical specifications of energy consumption and energy label of electric lamps | ISIRI 7341 | — |
• Energy label test |
`Standard Title |
ISIRI |
IEC |
Halogen tungsten lamps (non-automotive)Functional characteristics |
ISIRI 8290 |
IEC 60357 |
• Measurement of electrical and photometric parameters • Dimensional parameters • Caps and foundations |
||
Incandescent lamps-Safety requirements-Part 1: Tungsten incandescent lamps for household and similar general lighting use |
ISIRI 2910-1 |
IEC 60432-1 |
|
|
|
• Markings • Accidental contact protection • Increasing the temperature of the cap • Torque resistance • Insulation resistance • Aerial and creep intervals |
||
Tungsten Incandescent Lamps for General Lighting Applications |
ISIRI 115 |
IEC 60064 |
Measurement of electrical and photometric parameters • Radiation intensity and angle test • Aging test (normal-accelerating) |
||
Criteria and technical specifications of energy consumption and energy label of electric lamps |
ISIRI 7341 |
— |
• Energy label test |
Standard Title |
ISIRI |
IEC |
||
Double cap fluorescent lamps – safety features |
ISIRI 9172 |
IEC 61195 |
||
• Markup • Random contact protection • Increased cap temperature • Dimensions • Insulation resistance and electrical endurance • IP check • Creep distances |
||||
Double cap fluorescent lamps – functional characteristics |
ISIRI 687 |
IEC 60081 |
||
• Measurement of electrical and photometric parameters • Radiation Intensity and Angle Test • Life measurement test (normal-accelerating) |
||||
|
||||
Functional regulation of self-contained ballast lamps for public lighting |
ISIRI 5916 |
IEC 60969 |
||
• Measurement of electrical and photometric parameters • Radiation intensity and angle test • Life measurement test (normal-accelerating) • Keying test • Thermal durability test (temperature cycle) |
||||
Self-contained ballast fluorescent lamps for use in public lighting – safety requirements |
ISIRI 5917 |
IEC 60968 |
||
•Mechanical endurance test (tensile bending-twisting torque) • Lamp Dimensions Test • Flame and Spark Resistance Test • Insulation Resistance Test • Electrical Endurance Test • Temperature Resistance Test • Lamp cap temperature rise test |
||||
Single Cap Fluorescent Lamps – Performance Characteristics |
ISIRI 5211 |
IEC 60901 |
||
• Measurement of electrical parameters • Lamp dimensional tests |
||||
Single cap fluorescent lamps -Safety features |
ISIRI 5212 |
IEC 61199 |
||
• Markings • Accidental contact protection • Increasing the temperature of the cap • Torque resistance • Insulation resistance Aerial and creep intervals |
||||
Criteria and technical specifications of energy consumption and energy label of electric lamps |
ISIRI 7341 |
— |
||
• Energy label test |
Standard Title |
ISIRI |
IEC |
Lights: General requirements and safety tests |
ISIRI 5920 |
IEC 60598-1 |
•Markup •Structure • Outer and inner wiring • Ground/electric shock connection • Resistance to dust intrusion, hard objects • Insulation resistance and electrical endurance • Aerial and creep intervals • Durability and heating test • Resistance to fire heat and creep path • Terminals |
||
Lights: General requirements and functional tests |
ISIRI 20873 |
IEC 62722-1 |
|
||
• Measurement of electrical and photometric parameters • Radiation intensity and angle test • Life measurement test (normal-accelerating) • keying test • Thermal Durability Test (Temperature Cycle) |
||
LED modules with general lighting applications -Functional requirements |
ISIRI 21006 |
IEC 62717 |
• Measurement of electrical and photometric parameters • Radiation intensity and angle test • Life measurement test (normal-accelerating) • keying test • Thermal Durability Test (Temperature Cycle) |
||
General Lighting LED Modules -Safety Features |
ISIRI 11721 |
IEC 62031 |
•Markup • Ground connection • Electric shock • Resistance to dust intrusion, hard objects • Insulation resistance and electrical endurance • Aerial and creep intervals • Resistance to fire heat and creep path • Terminals • Electrical parameters •Corrosion |
Standard Title |
ISIRI |
Ref No |
Equipment for public lighting purposes – Electromagnetic compatibility (EMC) safety requirements |
ISIRI 23079 |
IEC 61547 |
• Voltage dips test • Surge test • Burst test • Power frequency magnetic fields test • Radio frequency and electromagnetic fields test • ESD test • Harmonic test • Flicker test |
||
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
— |
BS EN 55015 |
|
|
|
Frequency Common Mode test EMI tests
|